SECTION 1 INTRODUCTION
2
The powerful FD 1791-01 Formatter/Controller is used to
encode and decode all data transfers to and from the disk
drives. It also provides for the generation and checking of
address marks, data marks, and the cyclic redundancy characters.
Write precompensation can be selected under software control at
three levels of intensity, providing flexible data recording.
Data separation is achieved by the use of a phase-locked loop to
insure maximum immunity to disk speed variation and to enhance
data recovery margins in both single and double density.
1.3 DEVICE SPECIFICATION
Power requirements: +7 TO +11 Volts 0.90 Amp. Typical
1.50 Amp. Maximum
+14.5 to +21.5 volts 25 Ma. Typical
50 Ma. Maximum
-14.5 to -21.5 volts 8 Ma. Typical
30 Ma. Maximum
System Port
Requirement:
One I/O port,
switch selectable 40,41,42,43 Hex
System Memory
Requirement:
1K Byte block
switch selectable
EOOO,E400,EPOO,ECOO,
FOOO,F400,FAOO,FCOO Hex
Recording Method: Single density in FM
Double density in MFM
External
Communication:
One EIA compatible input signal
One EIA compatible output signal
Disk Interface,
Connectors:
8" Drives
50 Pin Card Edge Connector
AMP P/N 888083-1
3M P/N 3415-0001
5" Drives 34 Pin Card Edge Connector
AMP P/N 583717-5
3M P/N 3463-0001
System Interrupts: Optional Feature,
Vector Interrupt on VIO* thru VI7*